feat(http): liveness and readiness probes with a drain window (CARD-17, #115)
CI / dco (pull_request) Successful in 5s
CI / runtimes (bun) (pull_request) Successful in 16s
CI / build (pull_request) Successful in 27s
CI / runtimes (deno) (pull_request) Successful in 20s
CI / runtimes (edge) (pull_request) Successful in 14s

createApp({ health: true }) serves GET/HEAD /__live__ and /__ready__.
Ready reports booting until boot() resolves, ok or degraded (from
app.degraded()) after that, and draining from the moment close() starts.

Probes are answered by the adapters, ahead of the request gate and of
handle(): Node in serve() (src/http/server.ts), the Fetch path in
app.fetch before it awaits the boot. Otherwise ready could never say
booting. Being ahead of the gate means maxConcurrentRequests never sheds
a probe (D14). Being ahead of handle() means no step, provider, plugin or
onError runs, and no lifecycle event is emitted, so logRequests and
metrics never see a probe. Security headers still apply, plus
cache-control: no-store. Other methods get 405 with Allow: GET, HEAD.

A probe through app.fetch before any boot starts the boot without
awaiting it. On the edge, or under a bare Deno.serve(app.fetch), nothing
else may boot the app, and an orchestrator that waits for ready before
sending traffic would wait forever.

health: { drainDelayMs } (D14) marks the app draining and keeps the
listener open for that long before connections drain. Without it, Node
closes idle keep-alive sockets at once, and a probe sees a reset rather
than the 503. The window is spent out of the close budget. serveDeno and
serveBun start the same window, through a symbol-keyed hook on the app,
before server.shutdown() / server.stop(false). workerd has no close(),
so it never reports draining.

While health is on, /__live__ and /__ready__ join the reserved-path
boot check that CARD-21 introduced, for local and mesh-spliced routes.
Invalid health values throw at createApp.

Signed-off-by: Diego Resendez <diego.resendez@zero-oneit.com>
This commit is contained in:
chrnx committed 2026-10-23 00:54:04 -05:00
1 parent 9977d14605
commit ba57568a84
15 files changed
+789 -10

No files matched your search

+1
View File
@@ -144,6 +144,7 @@ without growing the runtime dependency tree past `reflect-metadata`:
- **Resource ceilings, with safe defaults.** `limits` caps body size (`413`), multipart parts, concurrent Node connections (default `1000`; `<= 0` leaves connections unlimited), and the request / headers / keep-alive timeouts — defaulting to `30s` / `10s` / `5s`, tighter than Node's own two-minute default. `maxConcurrentRequests` is opt-in and applies per server or Fetch adapter instance; when set, excess in-flight requests receive `503` and `Retry-After: 1`. It bounds concurrently executing handlers, so a handler that never returns continues to hold its slot; on Node, a client disconnect releases that slot. Long-lived streams and WebSocket upgrades do not hold that request budget. When Node's connection cap is reached, excess sockets are destroyed without an HTTP response. Deno and Bun expose no equivalent active-socket cap, so enforce one at the deployment platform or reverse proxy there. WebSocket connections are bounded too: `maxWsMessageBytes` (default 1 MiB) closes a connection whose message is larger with `1009`, and `maxWsQueue` (default `16`) closes one that has that many unread inbound messages and receives another with `1013`, rather than dropping anything. Both are server-wide and must be positive integers. Node and Bun refuse an oversized message before buffering it (Bun before 1.4 drops the connection, so its peer sees `1006`; Bun 1.4 and later send `1009`); Deno and the edge check it after the runtime has received it. Worst case, a server buffers about `maxConnections × maxWsQueue × maxWsMessageBytes` of inbound messages — ≈ 15.6 GiB at the Node defaults.
- **Observability without an integration.** Every request carries an id and a trace id through every lifecycle event, each step reports its own duration, and `createApp({ logger })` accepts any logger — the default writes structured JSON. Nothing in core writes to `console`. Metrics and tracing exporters read the same stream from outside core.
- **Graceful shutdown, with a deadline.** `app.close()` drains in-flight requests and closes live streams and mesh links, then warns and force-closes whatever is still open after 10 seconds — so a stuck handler cannot hold a deploy open forever. Change the number per call with `close({ timeoutMs })` or for the whole app with `createApp({ shutdownTimeoutMs })`. Connection *draining* is Node-only; on Deno and Bun the server `serveDeno()`/`serveBun()` returns carries the same `close({ timeoutMs })`.
- **Liveness and readiness probes.** `createApp({ health: true })` serves `/__live__` and `/__ready__`. Readiness reports `booting`, `ok`, `degraded` (optional providers that failed) or `draining` (from the moment `close()` starts). Probes are answered ahead of the pipeline: they are never shed and never show up in lifecycle events or request logs. `health: { drainDelayMs }` keeps the listener open for that window after `close()` starts, so a load balancer reads the `503` before connections drain. The edge never reports `draining`, because it has no `close()`.
- **Shutdown is an extension point.** A provider that opened a pool closes it in `dispose()`; a plugin registers `onShutdown(...)`; an application that wants neither passes `createApp({ hooks: [{ onShutdown }] })`. All three land in one registry, run in reverse boot order — a `cache` that needs `db` closes first — and are *awaited*, unlike a `bus.on` listener. A failure is logged and the rest still run, because one broken teardown must not leave the process up. Everything happens inside `close()`'s deadline; `createApp({ teardownTimeoutMs })` reserves a slice of it when a connection must get its chance. *Not available on the edge* — workerd has no shutdown to hook.
- **The `SIGTERM` handler is yours to keep or to hand over.** All of the above runs from `close()`, and something has to call it — a container `SIGKILL`ed after its grace period skips every `dispose()` and reports nothing. Write the handler yourself and keep the control, or set `createApp({ handleSignals: true })` and the framework registers `SIGINT`/`SIGTERM` to close and exit for you. Off by default, because a library that installs process-wide handlers behind your back is worse than one that installs none. Turning it on also absorbs the last runtime difference an app has: `process.on` on Node and Bun, `Deno.addSignalListener` on Deno, and the matching `exit` for each — `listen()`, `serveDeno()` and `serveBun()` each wire it to the closer that drains *their* server. `close()` unregisters, so a second Ctrl-C ends a teardown that is stuck.
- **Testable by construction.** `createApp({ overrides: { db: fakeDb } })` swaps any node in one line.