1 Commits
Author SHA1 Message Date
chrnx e5d5fb801a feat(shutdown): opt into SIGINT/SIGTERM with createApp({ handleSignals })
CI / runtimes (deno) (pull_request) Successful in 18s
CI / runtimes (edge) (pull_request) Successful in 13s
CI / build (pull_request) Successful in 30s
CI / dco (pull_request) Successful in 4s
CI / runtimes (bun) (pull_request) Successful in 14s
The README promised shutdown was *"an extension point, not a SIGTERM handler you
write"*. Half of it was true: `dispose()`, `onShutdown` and `hooks` all deliver the
*content* of teardown, but nothing called `close()`, so every application still wrote
the handler — and wrote it three times, because the spelling is per runtime. Forget it
and the container is SIGKILLed after its grace period, every `dispose()` the registry
so carefully ordered never runs, and nothing reports it.

`createApp({ handleSignals: true })` registers SIGINT/SIGTERM to close and exit.

Off by default, and that is the design rather than caution: a library that installs
process-wide handlers behind your back is worse than one that installs none, because
when the process exits is the application's call. Both halves are now supported and
documented — keep the handler, or hand it over. What is not optional either way is
that *something* calls `close()`, and the README now says so instead of implying the
framework already had it covered.

Declared once on `createApp`, wired per runtime by whichever boot call runs:
`listen()`, `serveDeno()` and `serveBun()` each pass the closer that drains *their*
server to `app.handleSignals`, which returns a close that also unregisters. On Deno
that unregistering is load-bearing rather than tidy — a live `Deno.addSignalListener`
holds the process open, so an app that closed itself would otherwise hang.

Unregistering first also means a *second* signal falls through to the platform default
and ends the process at once. That is deliberate: Ctrl-C twice is the way out of a
teardown that is stuck, and swallowing it for the length of a 10s budget would read as
a hang. An orchestrator sends SIGTERM once and then SIGKILL, so it never gets there.

Tested against real processes, because a handler whose job is to exit its own process
cannot be fired by hand in the runner: Node covers SIGTERM, SIGINT, the double-signal
escape hatch and the default-off case; Deno covers `Deno.addSignalListener`/`Deno.exit`,
which is the API that actually differs. Bun shares Node's `process` path.

Closes #70.

Signed-off-by: Diego Resendez <diego.resendez@zero-oneit.com>
2026-09-01 09:09:56 -05:00
+6 -1
View File
@@ -43,7 +43,12 @@ describe('handleSignals registration', () => {
/** Boots the harness app, waits for its `ready` line, and resolves once it has exited. */ /** Boots the harness app, waits for its `ready` line, and resolves once it has exited. */
function runHarness(signal: NodeJS.Signals, env: NodeJS.ProcessEnv = {}, sendTwice = false) { function runHarness(signal: NodeJS.Signals, env: NodeJS.ProcessEnv = {}, sendTwice = false) {
return new Promise<{ code: number | null; signal: NodeJS.Signals | null; lines: string[] }>((resolve, reject) => { return new Promise<{ code: number | null; signal: NodeJS.Signals | null; lines: string[] }>((resolve, reject) => {
const proc = spawn('npx', ['tsx', 'test/interop/_signal-app.ts'], { // `process.execPath -r tsx/cjs`, not `npx tsx`: a wrapper puts the app one process further
// down, and on Linux the signal then lands on the wrapper while the app never hears it — which
// is exactly how this passed locally and failed in CI. `-r` rather than `--import`/`--loader`
// because it is the one form that works on both the Node 18 floor CI builds against and the
// current release.
const proc = spawn(process.execPath, ['-r', 'tsx/cjs', 'test/interop/_signal-app.ts'], {
env: { ...process.env, ...env }, env: { ...process.env, ...env },
stdio: ['ignore', 'pipe', 'inherit'], stdio: ['ignore', 'pipe', 'inherit'],
}); });