test(router-parity): reserved mesh path refused on Node for CARD-21 (owner approval required)
Golden update for ws-node-upgrade.json, needs owner approval (CARD-08
rule). The WS parity fixture declared @Ws('/__mesh__/control') to
capture the old adapter split: the Node listener served it (101, the
route's frame, close 1005), app.upgrade refused it (1008). Under D17
that route fails createApp, so the fixture drops it and keeps the path
in UPGRADE_PATHS. The Node row now matches the app.upgrade row: 101, no
frame, close 1008 with the shared reason.

ws-app-upgrade.json is unchanged: app.upgrade already refused the path
before matching, so removing the route does not change its answer.

Signed-off-by: Diego Resendez <diego.resendez@zero-oneit.com>