Files
chrnx 5da4b8efa5 docs: design, plan, and the execution record
The thinking behind the organism, versioned alongside the three code repos rather than
living only on one machine.

- AILED_General_Specification.md, the authoritative design, and the implementation plan
  the code was built from
- AGENTS.md, the project-wide rules, including the two that were learned the hard way:
  this is not a performance benchmark, and a null recorded early beats a claim propped up
  later
- the nine superseded module specs, each carrying a banner naming what replaced it
- .sdd/, the execution ledger and every task brief and report: each ruling taken, what it
  would cost if wrong, every correction, and every number verified independently

The three code repos are siblings, each its own repository, and are git-ignored here so
nothing is nested.
2026-09-02 13:17:39 -05:00

8.8 KiB
Raw Permalink Blame History

Task 8 report — claim A1

Status: complete. The result is a null, with a mechanism.

Deliverable: experiments/results/a1.md (the full tables and the audit trail). Code: experiments/a1.py, experiments/tests/test_a1.py, and two optional keyword arguments added to frozen._train. results/*.json is gitignored; the four run files are a1_sweep.json, a1_controls.json, a1_shuffle_k4.json, a1_shuffle_k16.json and reproduce from the commands recorded at the top of a1.md.

The two-part answer

Does affect move the gate? Yes, decisively. κ=1 moves mean g from 0.501 to 0.465 and triples its sd (0.025 → 0.068), which is the part that matters: the gate acquires input dependence it did not have. Saturation starts between κ=2 and κ=4 (12.4% of entity-steps below g<0.1 at κ=4, 26.4% at κ=16; never above 0.9 at any κ, which it cannot be, since a ≥ 0). The post-switch versus far-from-switch contrast — the claim's actual content, not the mean — is −0.078 at κ=4 on 16/16 seeds, against +0.0000 on 4/16 at κ=0. Lag by lag the gate is an exact mirror of the arousal transient.

The mechanistically important number: the learned part of the pre-activation, W_g[h‖M] + b_g measured with the forcing left out, sits at 0.000 ± 0.002 at every κ — the same value frozen.md §3 measured at κ=0. Gradient neither compensates for the forcing nor participates in it. −κa is not modulating a learned gating policy; it is supplying the whole of one that gradient descent never built. A1's premise holds exactly as the brief framed it.

Does moving it help? No, and at short lag it hurts. steady is flat across a 16-fold range of κ: 2.399e-05 at κ=0 to 2.428e-05 at κ=16, a 1.2% spread against an across-seed sd 40 times larger. Paired per seed, grp_k0 beats grp_k on 6–9 seeds of 16 at every κ, median ratio 1.00 — a coin flip with no trend.

The one sign-definite, κ-monotone effect in the file is a degradation. At matched lag 2 after a switch, grp_k0 / grp_k runs 0.96 → 0.89 as κ goes 1 → 16, on 14–16 seeds out of 16. Smaller at lags 5 and 10, absent at lag 0 (arousal has not risen yet), gone by lag 19.

The shuffled control, stated explicitly

Three controls at κ=4 and κ=16, 16 seeds each, replacing only the arousal the gate sees while the CPPN keeps the organism's own live affect: shuffled (permuted within each half, so the marginal is matched exactly in the measured window rather than in expectation), shifted (circularly rolled, which also preserves arousal's autocorrelation and breaks only its alignment with the switches), and const (the run's mean, i.e. −κa as a pure bias shift).

The control is well-formed: at κ=4, shuffled matches real's gate distribution to three decimals — mean 0.400 vs 0.400, sd 0.165 vs 0.164, frac g<0.1 0.124 vs 0.124 — while its post-vs-far contrast collapses from −0.078 to −0.001.

On steady, real affect is indistinguishable from shuffled affect: 5/16 seeds at both κ, mean ratio 0.98–0.99. There is no effect for the control to rule in or out.

On recovery[2], real affect is worse than shuffled on 15/16 seeds — 6% at κ=4, 8% at κ=16 — while shifted sits at parity (0.99 on 5–7/16). So the lag-2 degradation is genuinely about surprise timing, not a generic bias shift: it is the one thing correlating −κa with the switches does that a distribution-matched control does not, and what it does is make the error worse. (const reproduces about half of it at κ=16 and none at κ=4, which is the bias-shift channel appearing only once the constant is large enough to shut the gate outright: const at κ=16 is g = 0.103 ± 0.010, a different dead gate rather than an open one.)

Why the null, and what it costs the paper

frozen.md §1b established that the post-switch error excess belongs to the world's configuration transient — a stateless frozen model reproduces its shape at every lag — so no gating policy can shorten it. Memory's only contribution in this domain is temporal smoothing. A gate that opens on surprise spends exactly that smoothing at the moment it is worth most, which is the lag-2 harm. The mechanism works; the domain gives it nothing to do and a little to lose. This is the same conclusion headroom.md §6(c) and frozen.md §4 reached from the other two directions.

A1 as written does not hold on this domain, and it should be reported as a measured null about this domain and this budget.

Three things worth carrying forward

  • The forcing lever is real and now instrumented. Any replacement domain can be checked for A1 with the same measurement, and pre ≈ 0 gives the null a mechanism rather than an absence — which is a stronger statement than "no effect measured".
  • Arousal lags the event by ~12 steps. It is lower at the switch step (0.061) than far from one (0.106), because Affect.update compares the loss to a slow baseline; it peaks at lag 12 of a 20-step window. The gate therefore opens after the error has already risen. In a domain where timing matters, that lag is a design parameter (rho_a, rho_slow), not a constant, and it has never been tuned.
  • recovery[2] is where affect shows up at all. Whatever replaces this domain should be checked at short lag before its steady-state error is quoted; steady saw nothing that recovery[2] saw clearly on 15/16 seeds.

Incidental corrections to earlier files

At 16 seeds in the trained phase, frozen.md §5's decomposition reads capacity (rp_only / grp_k0_nostate) 3.04x mean, 2.71x median, 16/16 seeds and state (grp_k0_nostate / grp_k0) 1.19x mean, 1.11x median, 11/16 seeds. frozen.md reported 3.06x on 8/8 and 1.25x on 4/8 at eight seeds. The capacity row is unchanged; the state row is firmer than it looked at eight seeds and is still modest — five seeds go the other way and the median is 1.11x. It does not change frozen.md's verdict and it does not rescue a memory claim, but the "4/8" figure should be replaced by "11/16" wherever it is quoted.

Method notes, for review

  • The gate is reconstructed, and the reconstruction is verified, not assumed. Organism.forward returns only out(M), so a1.GateTrace rebuilds h from the public org.rp and asserts org.grp(h, M_prev, a) equals the M the organism actually returned — every step of every gated run, 2.18M assertions across 272 runs, none fired. test_gate_reconstruction_is_the_organisms_own_gate perturbs the reconstructed h by 1e-6 and requires the assert to fire, so the guard can fail.
  • _train was extended, not copied. Two optional keyword arguments (gate_arousal, on_step), both defaulting to off; with both off the loop body is the call sequence it always was, and test_train_copy_is_identical_to_regime_run still asserts it reproduces regime.run's metrics exactly. test_on_step_does_not_perturb_the_run pins that the instrumentation is read-only.
  • The replay path is checked rather than trusted. Replaying the arousal sequence the gate itself saw must reproduce the unhooked run bit for bit; this is asserted in a unit test, again by the driver on all 16 seeds at run time, and the real arm was separately verified identical to the sweep's grp_k4 / grp_k16 rows on steady and on all 20 recovery lags. Note the off-by-one this catches: _train records arousals[t] after the affect update, so it is one step later than what the gate consumed — replaying arousals rather than the gate-seen sequence would have silently produced a lag-1 control.
  • The gate contrast and the error contrast are measured on the same steps. far is regime._metrics's own steady_idx; post is the union of the 20 steps each switch opens, i.e. exactly what recovery[0..19] averages. Asserted in test_index_sets_match_the_metrics_the_error_is_measured_on.
  • 16 seeds, not 8. The brief's floor was 8; runs are cheap and the paired comparison is the whole result, so the budget went to seeds.
  • What was not changed: ../ailed is untouched, and no default in particles.py or regime.py moved. Every measurement is at the parameters Task 6 was reviewed under.

What Part C could not do

The real arm's arousal is closed-loop (it responds to that run's own errors) while the control arms replay a fixed sequence recorded from a different trajectory, so the arms diverge from step 0. This is inherent to the design — a causally-coupled signal cannot also be time-shuffled — and it is the intended contrast rather than a confound, since closed-loop coupling is surprise timing. It does mean the controls cannot separate "correlated with this run's surprises" from "correlated with a run's surprises"; nothing in the result turns on that distinction, because the headline comparison on steady is a null in every arm.